dBµV/m ↔ V/m Field Strength Conversion Table

Reference table of µV/m, mV/m and V/m from 0 to 140 dBµV/m in 10 dB steps.

Emission limits and measurements are written in dBµV/m while immunity test levels are written in V/m, so the same field strength has to be moved between the two units constantly. Field strength is an amplitude quantity, so the conversion uses 20·log₁₀.

Field strength conversion table (10 dB steps)

dBµV/mµV/mmV/mV/m
010.0011×10⁻⁶
103.1620.0031623.16×10⁻⁶
20100.011×10⁻⁵
3031.620.031623.16×10⁻⁵
401000.11×10⁻⁴
50316.20.31623.16×10⁻⁴
60100010.001
7031623.1620.003162
8010000100.01
903162031.620.03162
1001000001000.1
110316200316.20.3162
1201×10⁶10001
1303.16×10⁶31623.162
1401×10⁷1000010

Open the calculator → dBµV/m ↔ V/m Field Strength Converter

Formula

E(V/m) = 10^((E(dBµV/m) − 120) / 20)
E(dBµV/m) = 20·log₁₀(E(V/m)) + 120

Worth memorizing

  • 120 dBµV/m = 1 V/m (the most useful anchor)
  • 0 dBµV/m = 1 µV/m
  • 10 V/m = 140 dBµV/m, 3 V/m ≈ 129.5 dBµV/m
  • Doubling the distance is −6 dB in the far field

Common mistakes

  • Using 10·log₁₀. Field strength is an amplitude quantity like voltage, so it uses 20·log₁₀.
  • Confusing µV/m with mV/m. The difference is a factor of 1000, which is 60 dB.
  • Treating the receiver reading as the field strength. Add the antenna factor and cable loss, and subtract the preamp gain.
  • Scaling the 3 m and 10 m limits with the distance formula. Use the values in the standard: CISPR 32 fixes the difference at 10 dB, not the calculated 10.46 dB.

Related calculators

All conversion tables

Results and summaries are for reference. For certification and test reports use the latest official standard text and calibrated instrument data. Last updated: 2026-10-10