Current Probe dBµV ↔ dBµA Conversion

Convert receiver dBµV readings to conductor current in dBµA using the probe transfer impedance in dBΩ.

Type in any field and the others update automatically.

dBΩ
dBµV
dBµA
Conductor current
1000µA

Worked example

(Probe transfer impedance Z_T 0 dBΩ) Receiver reading 60 dBµV, Conductor current 60 dBµA, Conductor current 1000 µA

Formula

I(dBµA) = V(dBµV) − Z_T(dBΩ)
Use the Z_T value from the probe calibration certificate

How it works

A current probe turns conductor current into a voltage for the receiver; the ratio is the transfer impedance Z_T. It is used for cable current measurements such as common-mode currents on signal and communication lines or current-limit items in MIL-STD-461.

Practical tipZ_T varies with frequency, so enter the value for the actual frequency from the probe calibration certificate. The default 0 dBΩ here is only an illustrative value.

Related calculators

Related standards

Results and summaries are for reference. For certification and test reports use the latest official standard text and calibrated instrument data. Last updated: 2026-10-10