Before a product goes to an EMC lab, someone has to decide which standards it will be tested against. Get it wrong and the cost shows up later: a report the certification body rejects, a Class A result for a product that is sold to homes, or an immunity test nobody planned for. The CISPR emission standards are organized by product family, not by technology, so the starting question is not what is inside the box but what the product is and where it will be used.
Three layers: basic, generic and product standards
EMC standards come in three layers. Basic standards describe how to measure or test but set no limits or levels for any product: CISPR 16 for emission measurement apparatus and methods, and the IEC 61000-4 series for immunity tests such as ESD (IEC 61000-4-2), radiated RF (IEC 61000-4-3), EFT/burst (IEC 61000-4-4) and surge (IEC 61000-4-5). Product and product family standards pick from those methods and add limits, test levels, operating conditions and performance criteria for a defined group of products. Generic standards, IEC 61000-6-1 to IEC 61000-6-4, do the same for an environment (residential or industrial) and apply only when no product or product family standard covers the product. The order of precedence is simple: a product-specific standard takes priority over a product family standard, which takes priority over a generic standard.
The main CISPR emission standards at a glance
| Standard | Scope | Typical products | Classification | Immunity counterpart |
|---|---|---|---|---|
| CISPR 32 | Multimedia equipment (MME) | PCs, monitors, printers, routers, TVs, audio equipment | Class A or Class B | CISPR 35 |
| CISPR 11 | Industrial, scientific and medical (ISM) equipment | Industrial machines and controllers, laboratory instruments, medical electrical equipment, microwave heating, PV inverters | Group 1 or 2, Class A or B | Set by the product standard, e.g. IEC 61326-1, IEC 60601-1-2, IEC 61000-6-2 |
| CISPR 14-1 | Household appliances, electric tools and similar apparatus | Washing machines, vacuum cleaners, drills, electric toys, thermostat-controlled heaters | Limits by appliance type; tools graded by rated motor power | CISPR 14-2 |
| CISPR 15 | Electrical lighting and similar equipment | LED lamps, luminaires, LED control gear (drivers) | One set of limits | IEC 61547 |
| IEC 61000-6-3 / -6-4 | Generic emission, residential / industrial | Products with no product family standard | By environment | IEC 61000-6-1 / -6-2 |
CISPR 32 and CISPR 35: multimedia equipment
CISPR 32 replaced CISPR 13 (broadcast receivers) and CISPR 22 (information technology equipment), and CISPR 35 replaced CISPR 20 and CISPR 24 on the immunity side. The class depends on the intended environment, not on which limit is easier to meet. Class B is for equipment intended primarily for use in a residential environment; Class A is for everything else, and a Class A product must carry a warning in its user documentation that it may cause radio interference in a residential environment. Between 30 MHz and 1 GHz the Class B radiated limits are 10 dB lower than the Class A limits at the same distance, which is a large gap to close late in a project.
CISPR 11: industrial, scientific and medical equipment
CISPR 11 covers equipment that uses RF energy for industrial, scientific or medical purposes, and through product standards that refer to it, it also covers many products that do not generate RF intentionally. It splits equipment into two groups. Group 1 is everything that is not Group 2, which in practice includes most industrial controllers, laboratory instruments and medical devices. Group 2 is equipment that intentionally generates RF energy and uses it to treat materials or for similar purposes, such as microwave heating, RF welding and induction heating. Each group then has Class A (industrial and other non-domestic locations) and Class B (domestic premises and locations connected directly to the low-voltage network that supplies residential buildings). CISPR 11 is the emission reference in IEC 61326-1 for measurement, control and laboratory equipment and in IEC 60601-1-2 for most medical electrical equipment, so a laboratory instrument with an Ethernet port is usually tested to CISPR 11 rather than CISPR 32.
CISPR 14-1 and CISPR 15: appliances, tools and lighting
CISPR 14-1 targets products whose disturbances come from motors, switches and thermostats. Besides conducted emission on the mains, it traditionally measures disturbance power with an absorbing clamp on the mains lead from 30 MHz to 300 MHz, and it has a separate assessment for discontinuous disturbances: the short clicks produced each time a thermostat or switch operates, judged by their rate and duration. Its immunity counterpart, CISPR 14-2, groups products into categories according to their electronic content and power source. CISPR 15 covers lamps, luminaires and their control gear. With the move to LED lighting, switching drivers have become the main noise source, and in addition to conducted and radiated emission, CISPR 15 includes a magnetic field measurement with a large loop antenna below 30 MHz.
A step-by-step way to pick the standards
- Write down the primary function and the intended environment: residential, commercial and light industrial, or industrial. The environment decides the class, and the sales channel counts as evidence of intent.
- Look for a product-specific standard first, for example IEC 60601-1-2 for medical electrical equipment, CISPR 25 for vehicle components or IEC 61326-1 for measurement, control and laboratory equipment.
- If there is none, choose the product family standard by function: CISPR 32 and CISPR 35 for multimedia, CISPR 14-1 and CISPR 14-2 for appliances and tools, CISPR 15 and IEC 61547 for lighting, CISPR 11 for ISM equipment.
- Use the generic standards IEC 61000-6-1 to IEC 61000-6-4 only when no product or product family standard fits.
- For mains-powered products with an input current up to 16 A per phase sold in the EU, add harmonic current emission (IEC 61000-3-2) and voltage fluctuation and flicker (IEC 61000-3-3).
- For multifunction products, check whether one standard covers the combination; otherwise each function may need its own standard, for example an appliance with a built-in multimedia function.
- Check the edition that each target market currently recognizes, and the date after which the previous edition no longer gives a presumption of conformity.
How CE, FCC, KC and VCCI relate to the CISPR standards
CISPR publications are international documents and have no legal force by themselves. In the EU they appear as EN standards (EN 55032, EN 55011, EN 55014-1, EN 55015 and so on), and the ones listed in the Official Journal give a presumption of conformity with the EMC Directive.
| Market | Mark or scheme | Legal basis | Emission standards used | Who declares or certifies |
|---|---|---|---|---|
| European Union | CE marking | EMC Directive 2014/30/EU; Radio Equipment Directive 2014/53/EU for radio products | EN 55032, EN 55011, EN 55014-1, EN 55015 and other harmonized standards | Manufacturer, with an EU declaration of conformity; a notified body is optional |
| United States | FCC | 47 CFR Part 15 (unintentional radiators), Part 18 (ISM equipment) | FCC limits; Part 15 digital devices measured to ANSI C63.4 | Responsible party under SDoC, or Certification by a TCB |
| South Korea | KC | Radio Waves Act | National standards based on CISPR, e.g. KS C 9832 (CISPR 32) | Conformity assessment with the National Radio Research Agency (RRA), based on a designated lab's report |
| Japan | VCCI mark | Voluntary industry scheme for multimedia equipment | VCCI technical requirements based on CISPR 32 | VCCI member companies, using registered measurement facilities |
Two differences cause most surprises. First, the FCC does not require immunity testing for most Part 15 devices, while the EU and Korea do, so a product that passed FCC testing still needs immunity testing for CE and KC. Second, products with a radio transmitter fall under the Radio Equipment Directive in the EU, where EMC is usually shown with the ETSI EN 301 489 series, and under separate radio rules in other markets.
Common mistakes
- Declaring Class A for a product that will be sold to consumers, to gain 10 dB of room.
- Testing to a generic standard when a product family standard exists.
- Forgetting IEC 61000-3-2 and IEC 61000-3-3 for mains-powered products sold in the EU.
- Testing a Wi-Fi or Bluetooth product only to EN 55032 and EN 55035 and leaving out the radio EMC standard.
- Using a superseded edition after its withdrawal date in the target market.
Calculators used in this post
More posts